Outstanding Features Make You Stand Out
We play extreme caution to quality and utmost attention to detail, which makes our products so perfect.
We play extreme caution to quality and utmost attention to detail, which makes our products so perfect.
The main circuit unit and running product are coherent in interchangeability.
The operating mechanism can be separated from the whole circuit breaker for convenient and easy maintenance and fix.
No need of adjustment of driving unit; long-acting lubricating, reliable corrosion resistance, and high mechanical stability make low maintenance possible.
We apply German lubricating grease boasting lower starting torsion, stronger anti-aging and oxidation resistance.
Utilizing zinc-nickel alloy plating line with a German process to make sure our corrosion resistance is 5 to 7 times stronger than ordinary zinc-plating process.
This product can easily realize diverse arrangements and combinations to meet functions like expandability and control.
VSG-40.5 series vacuum circuit breaker is a new type of three-phase 50Hz according to the unique design concept and combined with the market demand and development, the rated voltage of indoor switchgear40.5kV, it can be provided to industrial and mining enterprises, powerplant and substation as the control and protection of electrical equipment,and is suitable for frequent operation.
Applying Ambient Conditions:
1. Ambient temperature: -25℃一+40℃
2. Relative humidity: the average humidity of a day should be no mare than 95%; the average humidity of a month should be no more than 90 %.
3. Saturated vapor pressure: the average pressure of a day should be no more than 2. 2kPa, the average humidity of a month should be no more than 1.8kPa.
4. Earthquake intensity: not exceed 8 degrees.
5. Height above sea level: ≤1000m(not including special requirements)
6. Environmental conditions: It should be used in the places without fire, explosion, serious filth, chemical erosion and violent ration.
No. | Item | Unit | Data | ||
1 | Rated voltage | KV | 40.5 | ||
2 | 1min rated short-duration power frequency withstand voltage | KV | 95 | ||
3 | Lightning impulse withstand voltage | KV | 185 | ||
4 | Rated frequency | Hz | 50/60 | ||
5 | Rated current | A | 630/1250/1600/2000/2500 | ||
6 | Rated short-circuit breaking current | KA | 20 | 25 | 31.5 |
7 | Rated short-circuit making current (peak value) | KA | 50 | 63 | 80 |
8 | Rated short-time withstand current | KA | 20 | 25 | 31.5 |
9 | Rated peak withstand current | KA | 50 | 63 | 80 |
10 | Rated short-time withstand current duration | S | 4 | ||
11 | Rated operating sequence | 0-0.3s-CO- 180s-CO | |||
12 | Rated short-circuit current breaking times | Times | 30 | ||
13 | Mechanical Life | Times | 10000 |