Home » Switching Devices »Earthing Switch » JN22B-40.5/31.5 Indoor AC High Voltage Earthing Switch/Ground Switch
  • earthing switch
earthing switch

JN22B-40.5/31.5 Indoor AC High Voltage Earthing Switch/Ground Switch

Model: JN22B-40.5/31.5

Description

JN22B-40.5/31.5 indoor AC high voltage ground switch is an advanced level product with high-tech parameters performance improved on the basis of JN22-40.5/31.5. After comprehensive evaluation, it conforms to GB1985 AC HV disconnect switch and earthing switch and IEC62271-102:2002, applies to power system of 40.5kV and AC 50Hz. Can be used with KYN61-40.5 and other types high voltage switchgear , also play a protective role in the high voltage electrical equipment overhaul.

  • administration.icon02
    Material

    Use epoxy resin insulators, conductive parts made of silver-plated electrolytic copper(99.9%).

  • administration.icon02
    Feature

    The blades are directly connected to the drive shaft. Contact elements are overdimensioned according to the requirements in order to guarantee, together with a high contact pressure between blades and contacts, a reduced ohmic resistance at the contact surface and a minimum metal wear-off during the life of the grounding switch, with the necessary robustness to withstand thermal and mechanical stresses under short-circuit conditions.

  • Overview
  • Technical Parameter
  • Drawing

JN22B-40.5 indoor AC high-voltage grounding switch is an improved product of the JN22 type grounding switch, and its performance has reached the domestic advanced level. The main electrical performance complies with the requirements of GB/T 1985 “AC High Voltage Isolating Switch and Grounding Switch” and IEC129. It is suitable for power systems with AC 50Hz of 40.5kV and below. It can be used with various types of high-voltage switchgear and can also be used as a high-voltage switch. Used for grounding protection during maintenance of electrical equipment. This type of switch can be used in conjunction with live display devices.

Normal usage conditions:
1. The altitude does not exceed 1000m;
2. Ambient air temperature: upper limit +40℃, lower limit -25℃;
3. The earthquake intensity does not exceed 8 degrees;
4. Installed in places without risk of fire, explosion, severe dust, chemical corrosion and severe vibration.

Item Unit Data
Rated voltage kV 35
Maximum voltage kV 40.5
Rated short-time withstand current kA 31.5
Rated short-circuit duration s 4
Rated short-circuit making current kA 80
Rated peak withstand current kA 80
Phases center distance mm 280, 300, 350, 400
Rated insulation level PF withstand voltage(1 min) kV Phase to earth 95
Lightning impulse withstand voltage Phase to phase 185